Lay out a drywall partition

The Drywall module draws partitions, linings and ceilings by the maker's system — studs, rails and boards laid out as the system says, with its published fire and acoustic rating — and counts the takeoff from the laid-out boards and studs.

Tool: Partition6 steps · 6 pictures

  1. Start from the set-out: an L of 3 m and 4 m sketched on the floor. Open the Drywall group on the rail and pick Partition. The tray's System lists the maker's systems, thinnest first, filtered by Fire class and Ra at least (dB); leave it on The model's default and Height at 2500.

    Start from the set-out: an L of 3 m and 4 m sketched on the floor. Open the Drywall group on the rail and pick Partition. The tray's System lists the maker's systems, thinnest first, filtered by Fire class and Ra at least (dB); leave it on The model's default and Height at 2500.
  2. Click the partition's line on the floor, point by point: the end of the short leg, the corner, then the end of the long leg.

    Click the partition's line on the floor, point by point: the end of the short leg, the corner, then the end of the long leg.
  3. Press Enter to end it. The partition is laid out by its system in one edit: rails, studs on their spacing and the boards on both faces, the corner resolved.

    Press Enter to end it. The partition is laid out by its system in one edit: rails, studs on their spacing and the boards on both faces, the corner resolved.
  4. Pick Opening, leave the tray on Door, and click two opposite corners of the door on the partition's face: the bottom corner at the floor, then the top corner. The studs and boards are laid out again around it.

    Pick Opening, leave the tray on Door, and click two opposite corners of the door on the partition's face: the bottom corner at the floor, then the top corner. The studs and boards are laid out again around it.
  5. Pick Modules on the top bar, then Drywall. Elements lists the partition with its system — here Placo's Cloison Placostil 72/48 — its length, height, area, openings and rating, EI 30 and Ra 42 dB.

    Pick Modules on the top bar, then Drywall. Elements lists the partition with its system — here Placo's Cloison Placostil 72/48 — its length, height, area, openings and rating, EI 30 and Ra 42 dB.
  6. Open Takeoff: boards, studs, rails, screws, anchors, joint tape and compound, beads and insulation, with the quantity laid out, the quantity to order and the rule each is counted by.

    Open Takeoff: boards, studs, rails, screws, anchors, joint tape and compound, beads and insulation, with the quantity laid out, the quantity to order and the rule each is counted by.

Good to know

  • Opening also cuts a Window, Duct or Hatch: choose it in the tray's Opening list before clicking the corners.
  • Lining on a wall: click a wall's vertical face, and the lining is fixed to it and follows it when it changes. Ceiling: click the corners of the room, then the first one again, for a ceiling at the tray's Ceiling height.
  • IFC4 and Takeoff CSV on the Drywall page download the elements and the takeoff.
  • The ratings are the makers' tested figures, valid only as built to their report — not a certification.

Recorded in Kozorosa by the help recorder, which checked that the result is in the model.