Help centreModules

Lay out the ventilation of a flat

The HVAC module lays out a dwelling's mechanical ventilation in one click — extract outlets, air inlets, the unit, its ducts and the roof outlet, by the rules of the market — sizes the ducts, and shows each room's flows and the fan's operating point.

Tool: Design ventilation5 steps · 5 pictures

  1. Start from the rooms of a flat drawn as spaces with the MEP group's Space tool: living room, bedroom, kitchen, bathroom, WC and entrance. Open the HVAC group on the rail and pick Design ventilation.

    Start from the rooms of a flat drawn as spaces with the MEP group's Space tool: living room, bedroom, kitchen, bathroom, WC and entrance. Open the HVAC group on the rail and pick Design ventilation.
  2. In one edit, each kitchen, bathroom and WC gets an extract outlet at its ceiling, the living room and bedroom get air inlets on their outside walls, and the unit above the service rooms is joined to every outlet by its duct, with the exhaust out through the roof.

    In one edit, each kitchen, bathroom and WC gets an extract outlet at its ceiling, the living room and bedroom get air inlets on their outside walls, and the unit above the service rooms is joined to every outlet by its duct, with the exhaust out through the roof.
  3. Pick Size network in the HVAC group: every duct is given the size the rules ask for the air it carries.

    Pick Size network in the HVAC group: every duct is given the size the rules ask for the air it carries.
  4. Pick Modules on the top bar, then HVAC. The Ventilation tab gives each room's flow as the rules ask and as installed, the dwelling's minimum total and the air inlets against the air extracted.

    Pick Modules on the top bar, then HVAC. The Ventilation tab gives each room's flow as the rules ask and as installed, the dwelling's minimum total and the air inlets against the air extracted.
  5. Open Airflow: each duct's flow, velocity and pressure loss, the index circuit, and the fan's operating point against what the network needs.

    Open Airflow: each duct's flow, velocity and pressure loss, the index circuit, and the fan's operating point against what the network needs.

Good to know

  • Design ventilation run again on a model that already has HVAC equipment lays the ventilation out anew, replacing what it laid.
  • The ventilation system — self-regulating, hygro A or B, double flow — is the organisation's default from its HVAC settings; a model keeps its own, changed on its HVAC page.
  • Emitter places a radiator: click its connection end on the wall at floor level, then a point in the room. Size radiators on the HVAC page sizes them on each room's heat load.
  • Room loads come from the Thermal module when it is there, else from what is entered per room, else from a rough estimate the Heating tab labels as such.

Recorded in Kozorosa by the help recorder, which checked that the result is in the model.