Work out the heat loss of a flat

The Thermal module works out a building's envelope and heat loss from its rooms — U-values by EN ISO 6946, thermal bridges, heat loads by EN 12831 — checks condensation by Glaser, and exports the envelope to the thermal software that certifies it.

Tool: Compute4 steps · 4 pictures

  1. Start from the rooms of a flat drawn as spaces with the MEP group's Space tool, with their windows and the département, here the Rhône. Open the Thermal group on the rail and pick Compute: the heat loads and the check are worked out, and the message gives the building's heat load and the points to check — here 3.9 kW and 18 — with a link to the Thermal page.

    Start from the rooms of a flat drawn as spaces with the MEP group's Space tool, with their windows and the département, here the Rhône. Open the Thermal group on the rail and pick Compute: the heat loads and the check are worked out, and the message gives the building's heat load and the points to check — here 3.9 kW and 18 — with a link to the Thermal page.
  2. Pick Modules on the top bar, then Building thermal. Heat loss gives each room's inside temperature, area, transmission and ventilation losses and heat load, and the building's total, at the département's base outdoor temperature.

    Pick Modules on the top bar, then Building thermal. Heat loss gives each room's inside temperature, area, transmission and ventilation losses and heat load, and the building's total, at the département's base outdoor temperature.
  3. Open Envelope: every wall, floor and ceiling of every room, what lies beyond it, the way it faces, its area, its U-value and the build-up it takes.

    Open Envelope: every wall, floor and ceiling of every room, what lies beyond it, the way it faces, its area, its U-value and the build-up it takes.
  4. Open Calculator and choose a build-up in Start from: its layers are listed from the outside in, with the U-value, the insulation's R, and the condensation risk with its Glaser diagram. Change a layer to see the U-value follow.

    Open Calculator and choose a build-up in Start from: its layers are listed from the outside in, with the U-value, the insulation's R, and the condensation risk with its Glaser diagram. Change a layer to see the U-value follow.

Good to know

  • Settings on the Thermal page sets the département, the ventilation and the airtightness the heat loss counts.
  • Construction on the rail gives timber-frame or CLT walls and floors another build-up — the model's or the library's — instead of their own layers.
  • Linear bridge and Point bridge add a thermal bridge the junctions do not cover — a beam through the insulation, a bracket — counted in the room it lies in.
  • Exports writes the envelope as gbXML or CSV, and a calculation note, for the thermal software that does the regulatory calculation.